PdMA

$10,000+

per hour. The average cost of unplanned motor failure.

Motor Testing Equipment

Test all 6 fault zones of any electric motor—online or offline, without disconnecting. PdMA’s patented Motor Circuit Analysis catches winding, rotor, and power quality issues weeks before catastrophic failure.

Complete Motor Diagnostics

6

fault zones. One instrument.

Power Quality
Stator Winding
Rotor
Air Gap
Insulation
Connected Equipment

The only portable tester that covers all six.

Authorized PdMA Distributor

Middle East & Africa

Motor Range

Fractional–100K+ HP

Testing

Online & Offline

Motor Types

AC, DC & Synchronous

The Business Case

What changes when you can see inside every motor

01

Catch faults weeks before failure

Motor Circuit Analysis detects developing faults in stator windings, rotor bars, and insulation long before vibration or temperature changes appear. You schedule the repair—not the other way around.

Reported Impact

70–80%

reduction in unplanned motor downtime with regular MCA test programs.

02

Test without shutting down

Online testing captures motor health while running under load—no disconnection, no production interruption. Offline tests go deeper during scheduled outages. Both modes in one portable instrument.

Capability

Zero downtime

for online testing. Measure power quality, current signature, and demodulated spectrum under load.

03

One instrument for your entire fleet

AC induction, synchronous, wound rotor, DC—from fractional HP to over 100,000 HP. One tester, one software platform, one training investment. No patchwork of specialized tools.

Coverage

All motor types

AC induction, synchronous, wound rotor, and DC motors up to 1000V AC/DC.

Not sure which model fits your motors?

Our engineers have configured PdMA testers for plants across the Middle East and Africa.

Talk to an Engineer

Specifications

Side-by-Side Comparison

Parameter MCE MAX Flagship MCEMAX+
Motor Types AC Induction, DC, Wound Rotor AC Induction, Synchronous, DC, Wound Rotor
Voltage Range Up to 1000V AC/DC Up to 1000V AC/DC
Motor Size Fractional HP to 100,000+ HP Fractional HP to 100,000+ HP
Online Tests Current analysis, power, demod spectrum Current analysis, power, PQ, demod spectrum
Offline Tests Resistance, impedance, insulation, capacitance Resistance, impedance, insulation, capacitance, PI
Rotor Analysis Demodulated current spectrum Enhanced demod + current signature
Data Storage Internal + USB export Internal + USB + network

In the Field

How maintenance teams use PdMA

Predictive Maintenance

A cement plant catches a stator fault 3 weeks before failure

Routine MCE testing on a 2,000 HP kiln drive motor reveals phase-to-phase insulation degradation trending toward breakdown. The maintenance team schedules a rewind during a planned kiln outage—avoiding an estimated $280,000 in lost production.

Incoming Inspection

A refinery rejects a rewound motor before installation

Baseline MCE testing on a freshly rewound 500 HP pump motor reveals a turn-to-turn short in one phase. The motor goes back to the shop for correction instead of failing six months into service.

Power Quality

A data center traces premature motor wear to voltage imbalance

Online MCE testing on chiller motors reveals a 4% voltage imbalance—enough to halve motor life. The supply issue is corrected, extending the life of 40+ critical cooling motors across the facility.

Fleet Management

A water utility prioritizes its 600-motor maintenance budget

Annual MCE surveys across 12 pump stations build a trending database. Motors are ranked by fault severity score, focusing limited maintenance dollars on the machines that actually need attention—not arbitrary time-based schedules.

Stop guessing. Start testing.

See PdMA on your motors.

We’ll bring an MCE MAX to your plant and test your most critical motors. No obligation—just data you can act on.